3 to 5 layer co- extruded composite material made from UV & FR reinforced PP woven fabric
with one side special highly reflective metalized film.
Property | Test Method | Unit | Results |
---|---|---|---|
Grammage | ISO 536 | g/ sqm | 100–115 (+/-5%) |
Tensile–MD and CD | ASTM D828 | N/25 mm | 260 |
Burst Strength | ASTM D 774 | N/25 mm | 250 |
Water Vapour Transmission |
ASTM F 1249 |
N |
<1 |
Temperature resistance | ASTM C 1263–29˜66 ´C | - | Remains Flexible No Delamination |
Reflectivity | ASTM E408 |
% | 97% |
Emissivity | ASTM E 408 | % | 0.03 |
Working Tempreture | Celsius | -50 to 110’C |
Our SunPro®METW insulation are mainly used under roof decking, under attic rafters, over existing attic insulation, in floors, walls and crawl spaces, and in industrial and commercial buildings to block radiant heat coming into house through the roof during the summer and retain indoor heat generated during the winter. Also used as a moisture vapor barrier in air conditioning ductworks and cold rooms. It is used as packing material for big machine to prevent moisture and radiant heat to contact machine.
1.Above data are typical results and not the guaranteed performance.
2.Tolerance: Weight and Thickness: ±10%; Width: ±2mm; Length: ±0.5%.
3.The products should be stored at room temperature away from wet and heat source.